Electrical Steel Test Laboratory

Following tests are performed in ENPAY Accredited Laboratory under climated conditions.

  • Magnetic Properties of Electrical Steel and Strip by means of Epstein Frame according to IEC60404-2
  • Magnetic Properties of Electrical Steel and Strip by means of single sheet tester according to IEC60404-3
  • Surface insulation resistance of Magnetic Sheet and Strip according to IEC60404-11

Climate Conditions of Laboratory:

Temperature              : 23 ± 2 °C

Relative Humidity      : 45 ± 10 % Rh

 

Enpay performs the tests with following Uncertainty:

Uncertainity for Magnetic Steel Sheet Measurement with Epstein Frame;

 

Iron Loss

 

Bmax (mT)

Loss (W/kg)

 

1700

±0,033278